Ricoh DD5450(GES 7450) Report Code E-006

Visitor 317 0
DD_5450c_5440c
Symptoms:
Boot report E-006 code

Reason:
Poor stamping motor
Imprint sensor bad
Bad motherboard and power board
Dirty pulse disk

Maintenance process and solutions:
Most of the E-006 codes are caused by dirty pulse discs, so the fault persists after the repairman cleans the pulse discs after opening the back cover of the machine. Then replace the motherboard, power board after the failure remains unchanged.
In fact, the embossing encoder disc, embossing encoder sensor and embossing center sensor are located on one side of the paper outlet and need to remove the paper discharge cover plate of the paper outlet part to see them. Therefore, the cleaning work done by the repairman before did not do the point.
After removing the cover plate of the paper discharge unit (left) as shown in the figure below, you will see the pulse plate in the red circle in the right figure below. Most of this code is due to the failure of the pulse plate and sensor after being soiled with paper powder. The machine is normal after cleaning in this case.


Tags: #E-006 #5450 #Motherboard #Power board #Ricoh

Leave a comment