Ricoh MP2501L machine reported SC390 code

Visitor 395 0
The Ricoh MP2501L machine reports an SC390 code, which can be resolved by shutting down and restarting. The explanation for the SC390 code in the maintenance manual is: TD sensor error. During the copying process, the output of the TD sensor remained below 0.2 V or above 4.0 V for 10 consecutive times.
  • In SP2-220, the VT data was found to be 0.01. After continuously copying the blackboard and checking the VT data again, there was no change.
  • Replace the new PCDU unit and carrier, and perform carrier initialization using SP2-801-001. Surprisingly, the VT data is 0. Continuously copy the blackboard and check again to see that the VT data becomes 0.03.
  • Replace the PCDU test with another normal machine and the fault persists.
  • Replace the BICU board, high-voltage board, power board, and printing control board in sequence to test for the same fault symptoms.
    • After replacing the TD sensor socket wire on the machine (part 21 in attachment 1), the test was normal. However, the wiring harness of the replaced socket was measured with a multimeter and found to be normal. There were no short circuits or deformations of the contact pins. Due to the back and forth pulling of the blackboard for testing, the newly replaced PCDU unit experienced serious carrier leakage (with evenly distributed carriers on the printed material). The final solution was to replace the TD sensor socket harness on the machine and replace the carrier again to solve the problem.


Tags: #390 #2501 #Ricoh