Ricoh: MPC3004SP/3504SP/4504SP/6004SP Symptoms After the MPC6004SP is turned on, it is sometimes used normally, and sometimes the machine warms up for a long time after it is turned on. There is no "ready" display under the copy interface. If you click the "Start" button, the machine will appear SC551-01 or SC552-02 code. Diagnostic process 1) Refer to the Service Manual for SC code interpretation: Infrared temperature sensor (edge) disconnected Continuously detect below -50 degrees Celsius (or below CB) for a specified time (seconds).
2) Check and reinstall the wiring plug at the rear of the machine (BCU/IOB/IPU/CTL). The fault persists. 3) replace the fixing unit, the fault remains. 4) Replace the two infrared temperature sensors, the fault remains. Solution: The machine is normal after replacing the power board. The power board is faulty, and the machine is normal after replacing the power board. |