Prompt for SC495 code when copying Refer to the service manual and the code is explained below: According to the manual prompts, check the toner recovery motor and the toner used up sensor, use the SP5804-054 to test the waste toner motor, the motor rotates normally, and check the waste powder circulation sensor:
Check the transfer waste powder recovery sensor, normal
Start-up inspection found that the transfer waste powder recovery spiral tube does not rotate, hand touch the lower part of the waste powder conveying hose found that there is a hard agglomeration inside the hose, remove the inspection found that there are more toner agglomeration in the transfer spiral tube. Reason Transfer waste powder recycling spiral tube toner agglomeration, resulting in spiral tube does not turn. Solution Clean the transfer waste powder recovery spiral tube and replace it if necessary. |