Symptoms: After a IMC3000 machine is turned on for 10 seconds, a Japanese prompt fault appears on the panel. The machine cannot start normally and the self-test has no action and cannot be used. The check status light shows red (the machine panel shows the figure below). Reason Error definition: SC667-01. Master device mode setting error. The machine detects a CPU mode error while starting up or resuming from power saving mode.Maintenance process: 1. First of all, the engineer goes to the site to check the status of the machine display SC667-01. 2. Check the connection of controller, SOP, BICU and flat cable to IOB respectively. 3. On-site exchange test SOP screen failure is still. 4: By exchanging the BICU board, the machine startup display is normal. Solution: After replacing the new BICU board and upgrading the firmware to the latest. https://www.aliyundrive.com/s/Az5EyyBj45U |