According to the manual explanation. Sc101-05 is an exposure lamp error. Lift the platform to check the reset action, and the exposure lights are all on. Turn on the glass and check if the exposure light moves smoothly without any lag, everything is normal. The exposure lamp tube LED can also all light up. Try restarting the machine. The malfunction persists. Error sc101-05, alcohol cleaning exposure lamp tube connection cable. Reverse colored glass. Scanning and other methods cannot solve the problem. Finally, open the back cover of the machine and remove the NVRAM from the BICU. Clean the contact points of the octagonal chip with alcohol, then plug it back in and turn it on again. Everything is normal. After using it for two months, the fault was not reported and missed. Upon discovery. After using 9003sp for 10 million prints, most of them will report this fault code. |
Tags: #sc101-05 #Exposure lamp #7503 #9003 #Octagonal chip