The SC673-10 code is reported during machine use. From the code explanation in the manual, the fault should be related to the connection and settings of the operation panel: Measures: 1. Check the connection between the host and the operation panel. 2. Check and confirm: Set the SP5748-201 connection setting on the operation panel to 1. 3. After replacing the control panel for testing, the fault persists. 4. Replace the controller board and the fault disappears. Solution: Replace the controller board and the fault disappears. Note: When replacing the controller board, pay attention to correctly installing the original NVRAM. |