Ricoh IMC2510 Boot Error Reporting SC371-01

Visitor 382 0
Symptoms
A Ricoh IMC2510 startup error SC371-01 cannot be resolved by turning it on or off.

Possible causes:
ITB issues/ID sensor issues/board routing issues

Maintenance process
1. Check the historical SC records in SP7403, only SC371-01;
2. Check the Gamma value of SP3630, all four colors are within the standard range, but execution of SP3011-002 and 001 has failed;
3. After executing the four PCDUs and transfer belt units in 3701, the fault persisted during the startup test;
4. After cleaning and inspecting the ID sensor, the fault persists during testing;
5. Swap the ID sensor (middle) with the ID sensor (front) for testing, and the fault persists;
6. Check that the initialization results of the ID sensors in SP3323 are all 555. Check that the data of the three ID sensors in SP3322 are close, and execute SP3320 to display a failure;
7. Search for the dot plot and check the ID sensor harness of CN218 on the BICU. It was found that there was a virtual connection. After unplugging and testing again, it turned on normally;
8. All functions of the MFP were tested and found to be normal, and any malfunctions were resolved;

Solution
The issue caused by the virtual connection of the BICU harness should be resolved after re plugging and unplugging;

Tags: #C2510 #SC371-01 #BICU #Harness loose connection #c3010