Symptoms The SC672 code appears when the machine is turned on, the SP mode cannot be entered, and the operation panel buttons do not respond. Reason Poor connection between GW controller board and IPU board. Solution Tighten the connecting screws on the GW controller board and the controller box. Maintenance process: 1. The SC672 code appears when the machine is turned on, and the SP mode cannot be entered, and the operation panel keys have no response; 2.SC672 code for machine startup failure, poor connection between controller board and operation panel; 3. The fault of reseating the connector between the controller board and the IPU board is not eliminated; 4. Check that the 5V and 12V voltages output by the power supply board of the controller board are normal through a multimeter; 5. Replace the controller board memory and hard disk test failure is still; 6. Careful inspection found that the fixing screws of the machine controller box and the fixing screws of the controller board were not completely fixed, resulting in poor connection between the controller board and the IPU board. The fault was solved after the above screws were fixed again. |
337
0
Address of this article:https://073868.com/post/5374.html
Copyright Notice:
For relevant infringements, reports, complaints and suggestions, please send E-mail:weixiuwang68@qq.com