|
Explanation of the repair measures to be taken when E061-0001 or E061-0003 occurs. [Failure Phenomenon] Error codes E061-0001 or E061-0003 occur. -E061-0001: One charge dark part potential error -E061-0003: potential control dark part potential error [Cause of Failure] Several diodes are used in the transformer on the primary charging high-voltage board assembly (BK)[1], some of which have chips contaminated by foreign objects. If these diodes with excessive foreign matter content are used in transformers, they will cause short-circuit and non-conductive problems during use of the host.
[Service Operation] 1) When the above failure phenomenon occurs, please refer to the description of "Removing the rear lower cover unit" in the "Maintenance Manual" to remove the rear lower cover unit. 2) Remove the old one-time charging high-voltage board assembly (BK) and replace it with the new one-time charging high-voltage board assembly (BK). Then reinstall the rear lower cover unit.
|
321
0
Address of this article:https://073868.com/post/5087.html
Copyright Notice:
For relevant infringements, reports, complaints and suggestions, please send E-mail:weixiuwang68@qq.com
Previous articleHP P1007 printer paper jam without reason

