|
Caution when replacing the left and right 24V power supply boards of the imageRUNNER ADVANCE 6575,6565,6555 Product model: imageRUNNER ADVANCE 4500 Series imageRUNNER ADVANCE 4500III Series imageRUNNER ADVANCE C3500 Series imageRUNNER ADVANCE C3500III Series imageRUNNER ADVANCE 6500 Series imageRUNNER ADVANCE 6500III Series imageRUNNER ADVANCE C5500 Series imageRUNNER ADVANCE C5500III Series imageRUNNER ADVANCE C7500 Series imageRUNNER ADVANCE C7500III Series iR-ADV C7580/C7570/C7565 Theme countermeasure solution The problem of shaking of the touch screen icon Trouble Phenomenon When you touch the control panel, the icons on the display may shake. Reason When the display screen is touched, the conversion of the coordinate information may not be completed correctly, and in this case, the above-mentioned problem may occur. Theme Precautions when replacing the capacitive control panel assembly on site due to production completion. Detailed description Due to procurement reasons, some parts of the flat operation panel have changed. According to this change, the planar operation panel was changed from a capacitive panel to a resistive panel. When replacing the flat capacitor type operation panel, the following 13 parts must be prepared to be replaced at the same time. Please refer to (iRA 6500 Series_Replacing Resistance Type Control Panel Steps) for specific replacement. imageRUNNER ADVANCE 6575,6565,6555 replacement resistance screen control panel unit and motion sensor unit Theme Prevent 0047 jam caused by damage to the DF driver board Fault phenomenon When installing or moving the main unit, if you touch the heat dissipation [a] position on the back of the ADF, static electricity may be generated. If the black clamp connector [1] of the motor (M6) cooling fan cable is close to the heat dissipation hole, static electricity may be conducted to the DF drive PCB assembly, causing IC damage and 0047 jam. To prevent 0047 jam, please refer to [Maintenance] to check the position of BK clamp [1] of motor (M6) cooling fan cable when installing or moving the main unit. If it is not suitable, replace it in time. When moving the host, be sure not to touch the heat dissipation holes on the back of the ADF. Link: https://pan.baidu.com/s/1ICDsBO_73lZy-Q_TRRZLCA Extraction code: 5s7e |
354
0
Address of this article:https://073868.com/post/5085.html
Copyright Notice:
For relevant infringements, reports, complaints and suggestions, please send E-mail:weixiuwang68@qq.com
Previous articleFujifilm 2150N/ 2350NDA Whiteboard Calibration Method Sharing after Replacing Motherboard
NextKyocera TASKalfa MZ4000i,MZ3200i Chinese repair manual parts manual