Xerox AP DC V C7775, C6675, C5575, C4475, C3375, C3373, C2275 Technical Information
The Seito T2 is a successor model of Seito that began selling in the Chinese market in July 2014. What we mean by Seito T2 and Seito FO is the same, just different names. The meaning of T2 is Type 2, and the meaning of FO is Follow On. To identify whether the repaired model is Seito T2 on site, the following three methods can be used to check: 1. When you open the front cover of the machine, you can see that T2 is Seito T2, and if not, it is Seito T2 When the startup screen starts up to 5/6, if T2 appears, it is Seito T2, and if not, it is Seito 3. Print the machine configuration report. If the report shows that the model is T2, it is Seito T2, and if not, it is Seito T2 Note: Due to the fact that Seito's DMP platform is DMP XI and Seito T2's DMP platform is DMP XI-1c, there may be slight differences in functionality between the two machines. We should pay attention to the model when installing the hardware on which the relevant functions are based. There are also two machines with slightly different requirements for the installation of optional components. When installing, you should also check the relevant PLI or LPG files and upgrade the maintenance manual to the latest version.
The 24V signal that controls the 220V output from the MD board is missing (J412 B1, Figure 1). Tracing back, it was found that this signal had already disappeared before passing through the fixing overheat protection (J431 17, Figure 2). But the 24V input of the MD board is normal.
When the DADF-130 of ApeosPort/OcocuCentral-V C7775/C6675 (including T2 models) experiences a paper jam fault of 005-123, please troubleshoot by replacing the Retard Chute instead of replacing the entire DADF component
Seito's machine, the second day after the opening of EPBB, the error light is always on Content On the day after EPBB is enabled, if the machine’s error light remains on continuously, there are typically two possible causes: 1. EP communication is not normal, and the communication failure prompt takes about 5 minutes to be displayed on the machine. 2. Turn off the power supply before the communication failure prompt appears, and EP communication still fails after 5 minutes after starting up again. In the above case, the NVM920-093 will change (to a number other than 0 depending on the cause of communication failure). The machine error indicator will always be on and cannot be removed even if the NVM920-001(EP setting status) is changed to 0. If the EP communication fails continuously for 24 hours, the NVM920-092 will change (a number other than 0 depending on the cause of the communication failure). Solution 1. Check the NVM920-093. If it is not 0, change it to 0. 2. Check the NVM920-092. If it is not 0, change it to 0. NVM 920-092, 920-093 refer to chapter 6 of the Seito Service Manual for the various meanings of the corresponding values. Link: https://pan.baidu.com/s/1Wi18CmZwcUlyY04ybkvIfA Extraction code: xpsp |
326
0
Address of this article:https://073868.com/post/5067.html
Copyright Notice:
For relevant infringements, reports, complaints and suggestions, please send E-mail:weixiuwang68@qq.com
Previous articleXerox DPCP228w machine reported error "093-92X" toner concentration is low, manual toner addition method
NextXerox VII C7773/6673/5573/ 4473/3373/3372/2273 Resolves 124-372 Failure Caused by Memory Leak