Fault phenomenon:The machine is printing normally, but when copying or scanning, it prompts that the original scanning section may not be clean. Solution:1. Clean the scanning glass and CIS section, remove the draft table glass and clean the reflector with a dust-free cloth.2. In maintenance mode, read and write NVM, adjust 716-150 to 1000 or above. |