Xerox Apeos 256030603560 feeder DADF130 fault code 062 277

Visitor 379 0
Summary
This announcement introduces the latest models equipped with
A possibility and countermeasures for IPS DADFCommunication Fail (062-277) in the DADF130 model.

Cause of the failure
Partial configuration
During the opening and closing process of the DADF130 machine's document feeder, the communication harness between DADF and ESS (as shown in Figure 1 on the right) may be pulled. As the opening and closing times increase, the harness may break, increase resistance, and cause poor contact, resulting in occasional 062 277 communication faults.


Preventive measures and countermeasures
preventive measures
Please refer to page 5 for daily on-site maintenance and repair
Cut in the serial number, check if the machine is within range, and print an error record report to check if the 062 277 fault has occurred.
If not found
062 277 fault, please refer to page 24 to undo the buckle on the wiring harness connecting DADF and ESS, in order to avoid pulling the wiring harness during the opening and closing process of DADF.

Apeos 4570 / 5570
ApeosC7070 / C6670 / C5570 / C4570 / C3570 / C3070
952K 52692M00

Apeos C2060 / C2560 / C3060
Apeos 2560 / 3060 / 3560
952K 58461M00

Countermeasure plan
If a fault of 062 277 is found, please refer to the table in the upper right corner of this page. Based on the corresponding part number of the model, order the corresponding solution (blue communication harness) and replace it at your doorstep.





Tags: #062-277 #2560 #3060 #3560 #Document Feeder

Leave a comment