Summary This announcement introduces the latest models equipped with A possibility and countermeasures for IPS DADFCommunication Fail (062-277) in the DADF130 model. Cause of the failure Partial configuration During the opening and closing process of the DADF130 machine's document feeder, the communication harness between DADF and ESS (as shown in Figure 1 on the right) may be pulled. As the opening and closing times increase, the harness may break, increase resistance, and cause poor contact, resulting in occasional 062 277 communication faults.
Preventive measures and countermeasures preventive measures Please refer to page 5 for daily on-site maintenance and repair Cut in the serial number, check if the machine is within range, and print an error record report to check if the 062 277 fault has occurred. If not found 062 277 fault, please refer to page 24 to undo the buckle on the wiring harness connecting DADF and ESS, in order to avoid pulling the wiring harness during the opening and closing process of DADF. Apeos 4570 / 5570 ApeosC7070 / C6670 / C5570 / C4570 / C3570 / C3070 952K 52692M00 Apeos C2060 / C2560 / C3060 Apeos 2560 / 3060 / 3560 952K 58461M00 Countermeasure plan If a fault of 062 277 is found, please refer to the table in the upper right corner of this page. Based on the corresponding part number of the model, order the corresponding solution (blue communication harness) and replace it at your doorstep.
|
Tags: #062-277 #2560 #3060 #3560 #Document Feeder