A M5025 printer was reported for repair, but during the power on self-test, it reported an error of 50.03 or 50.04 in the condenser. Firstly, a single heating component was sent by 800, and after ASC came to replace the heating component, the fault persisted. ASC has performed multiple power on self checks and found that one of them was able to print a sheet normally. However, when ASC disassembled the machine, no abnormalities were found on the surface of the high-voltage board. ASC considered whether it was a wiring issue. When plugging in and unplugging the high-voltage board interface and the DC control board interface, it was found that one of the wiring was severely oxidized. A blade was used to cut off the oxidized part and re plug it. After power on testing, the fault disappeared. Case summary: This case was not resolved by replacing spare parts for the first time, but after careful observation by ASC, the thinking was promptly changed based on the fault phenomenon. ASC should observe the symptoms of faults when repairing machines, and use this as a basis to facilitate the resolution of faults. Tell customers to pay attention to improving the usage environment. |
Tags: #5025 #Thermal condenser error #Wire oxidation