Fault phenomenon:The C450i printed copy shows colored lines in all three colors, with yellow being particularly prominent. When the C450i color is output, there are CD direction (drum core parallel) lines with varying shades, with a line spacing of about 38mm. The yellow color of the lines is more prominent.
Cause of the failure: The surface wear of the drum unit causes abnormal control of the charging voltage of the high-voltage board. On site processing steps: 1. Block the laser output, and the copy also has lines in the blank space; 2. Due to the prominent yellow color, replacing the yellow drum component and reinstalling each developing component did not solve the problem; 3. Re plug and unplug the circuit, replace the laser components, transfer belt, high-voltage board, and substrate, but the fault persists; 4. Remove all drum components and developing components from the normal machine and install and test them normally. 5. Afterwards, the original developing and drum components were replaced separately for testing. When installing the C drum component, the fault reappeared and it was confirmed that the fault was caused by the C drum component. 6. Carefully inspect the drum components, there are obvious black circles on the surface of drum C (as shown in the attached figure), as well as on other colored drums. Upon closer inspection of the charging roller surface, there are also some improvements in the image effect after cleaning the drum surface and charging roller surface. It can be inferred that the color line malfunction in the image is caused by unstable output of the high-voltage board due to surface wear and charging leakage of the drum unit. Check the consumables usage information to confirm that the color drum unit of the machine has reached its service life.
|
Tags: #C450i #colorful lines #Toner cartridge #Developing