Content: In Local TI NO.10, we mentioned that after the engineer replaced the used Halftone PWB, a fault code 045-359 appeared due to a model mismatch (refer to Table 1 for the model). At that time, we requested the engineer not to use the previously used Halftone PWB, not to use other machine's Halftone PWB for testing, and also requested the engineer not to handle the return of the part. There is now a new solution for the replacement of Halftone PWB. Solution: When we switch to Halftone Tone PWBs from different models, the machine will experience a 045-359 fault. We can eliminate this fault by following the steps below: 1. Change NVM 740-005 from 0 to 127 2. Initialize IOT NVM 3. Restart the machine Once the 124-315 fault code appears after restarting, please execute DC132 |