ApeosPort/DocuCentre-VII C7773/6673/5573/4473/C3372/C2273 Overview: Introduction to the logical judgment of the waste powder box status of Botan/Botan 2/Beni models, and provide solutions for related faults Content: Recently, there have been several incidents on the site where the waste powder box inside the machine has been filled up with waste powder, but the UI does not provide a prompt message, and the waste powder box has not been replaced in a timely manner, resulting in blockage of waste powder and even wear of the photosensitive drum. For this purpose, this announcement will introduce the principle of determining whether the waste powder box of this series of models is full, and provide solutions to related faults. 1、 How to determine if the powder blockage fault is caused by the waste powder box being full without prompting: 1. Refer to BSD9.22, enter component control in engineer mode and confirm if the status of 091-201 (TONER BOTTLE FULL SENSOR) is H. 2. Take out the waste powder box and observe whether the plastic transparent window at the bottom of the tail end of the waste powder box has accumulated carbon powder. (Refer to Figure 1) 3. Whether the waste powder has accumulated at the entrance of the waste powder box (see Figure 2), and whether there is also a situation or trend of waste powder accumulation in the waste powder channel component on the front side of the machine (see Figure 3). If it is confirmed that the machine has the above three conditions, it can be judged that the amount of waste powder discharged by the machine is abnormal, and the powder blockage fault is caused by the failure to remind the replacement of the waste powder box in a timely manner.
2、 Principle Introduction: Unlike other EDS color machines, the waste powder box full sensor of the Beni/Botan/Botan2 model is designed at the bottom of the waste powder box tail end. When the waste powder is discharged to this sensor area with the stirring rod, the waste powder full sensor is triggered, but there is still a small amount of space in the upper middle of the waste powder box tail end to carry more waste powder. Therefore, after receiving the signal triggered by the waste powder full sensor, the machine will not immediately prompt the waste powder box full information. Instead, it will start counting the subsequent copy outputs based on two parameters: print volume (PV) and ICDC (print coverage), and only issue the waste powder box full information after reaching the preset value, reminding customers to prepare and replace the waste powder box.
Please refer to the next page for the relevant control logic. 3、 Solution: When the machine is in a specific situation, such as high voltage leakage, excessive amount of carrier and powder in the developing chamber, etc., resulting in an abnormal increase in the discharge of waste powder, there will be a situation where the waste powder is full but still not prompted. For this type of problem, you can refer to the table on the right and adjust the corresponding parameters to lower the preset values until it is completely resolved.
Precautions: This TI also applies to Botan2 and Beni models. |
Tags: #The waste powder box is already filled with waste powder #C4473 #c6673 #c7773 #c5573