How to Deal with Flicker Problem and YE Error Problem of Epson CB-1485Fi and Other Models

Visitor 345 0
Handling methods for flicker and YE error issues of Epson projectors CB-1485Fi and other models

1. Related products
CB-1485Fi / CB-800F / CB-805F / EH-LS500B / EH-LS500W


2. Fault phenomenon:
1. Strobe issue
After turning on the projector for 10-20 minutes, the projected image flashes.
2. YE Error (Motor [16])
After turning on the projector for 10-20 minutes, a YE error occurs.
For example:


The meaning of this error is: the speed of the fluorescent wheel should be 3000rpm. But when the problem occurred, the fluorescent wheel had already stopped rotating.

3. Reason for the problem:
In CB-485Fi and EH-LS500B/EH-LS500W, due to the weak contact pressure of the connectors connected to the LMDR - affected circuit board assembly, the pins may oxidize due to friction, which may result in excessive contact resistance
Due to the situation, the affected circuit board and LMDR board are unable to communicate correctly.
<受影响电路板>
1485Fi:MABoard。LS500:EX1 Board
But this oxide film is very fragile and may break due to certain stimuli; For example: "Transportation vibration", "Disconnecting and reconnecting connectors on MAB", etc. Therefore, it is possible that this issue will not occur again at the repair center.
4. Temporary measures:
Due to partial oxidation of the connector, please replace the MAB board and LMDR cable according to the following settings before issuing permanent countermeasures.

Component code, component name
1870941                     MA BOARD ASSY;H919 P H;AS
1871462                     MA BOARD ASSY2;H921;AS
1870942                     MA BOARD ASSY;H923
P H;AS
1809818                     PCB ASSY;H922EX1;WITH P;AS
2213811                     CABLE,LMDR-MA-H919
P H

5. Permanent countermeasures:
5.1 Replace the connectors of the affected MAB board or EX1 board and LMDR cable (only on the MAB board side) with new ones.


*The connector of LSM remains unchanged. (The types of connectors are different.)
Note: In addition to this issue, you can continue to use the old circuit board for repairs.
5.2 Improved spare parts P/N and spare parts name
All old models will release new ASPs in the SPI system after leaving the factory.
Switching time: April 2023

Revised versionComponent codeComponent NameDescription



Old parts
1870941MA BOARD ASSY;H919P H;AS-
1871462MA BOARD ASSY2;H921;AS-
1870942MA BOARD ASSY;H923P H;AS-
1809818PCB ASSY;H922EX1;WITH P;AS-
2213811CABLE,LMDR-MA-H919P H-
1814859LSM ASSY;H919;AS-



New component
1916309MA BOARD ASSY2;H919P H;ASLMDRThe connector has been modified and the cable has been integrated into the assembly.
1916310MA BOARD ASSY2;H921P H;ASLMDRThe connector has been modified and the cable has been integrated into the assembly.
1916311MA BOARD ASSY2;H923P H;ASLMDRThe connector has been modified and the cable has been integrated into the assembly.
1916312EX1 BOARD ASSY2;H922P H;ASLMDRThe connector has been modified and the cable has been integrated into the assembly.
2227879CABLE,LMDR-MA-H919P H;2MABThe wiring harness on the side has been changed.
1916313LSM ASSY2;H919;ASLMDRThe connector is not included in this assembly.
1.1 New and old spare parts cannot be exchanged

Tags: #CB-1485Fi #CB-800F #CB-805F #EH-LS500B #Projector

Leave a comment