Summary FIERY standalone servers can only connect to the host momentarily at power-on, and then disconnect Reason NVM board failure on host ESS, troubleshooting after replacement Content The server can be connected to the IOT at the moment of startup and can obtain the host information, which is still the case after reinstalling the server software. It can basically be judged that the problem lies in the IOT part. In addition, the server can be tested to see if it is normal to connect to other hosts where conditions exist. If it is normal, the server problem can be directly eliminated and then the relevant IOT components can be tested step by step to find out the problem. Relevant knowledge points 1. For FIERY backpack server, when replacing the new hard disk, it should be installed in the server of other normal machines and then take back the faulty machine. During direct installation, the required installation program cannot be written into the new hard disk because the server's own program cannot start normally. 2. For fiery and cero servers, change NVM value 700-485,0 is fiery and 1 is cero |
Tags: #c700 #Server #Unable to connect IOT #Host