Code 047-311 when installing IFM and Finisher D4 on Xerox V80 new machine

Visitor 259 0
Subject: Code 047-311 when IFM and Finisher D4 are installed on a new machine

Summary:
The new machine is installed and configured with IFM and Finisher D4. After startup, IFM has no display FinisherD4 no initial action, and 047-311 code appears on UI. After restarting the machine, the fault remained.

Content:
1. Check that IFM LVPS has 220V input but no output; According to the BSDCH26.1IFM DC Power Generation, it is found that the J505 plug was not installed in place at the factory. After correct insertion, the IFM LVPS output is measured to be normal, but the 047-311 code still appears after the machine is started.
2. Upgrade the latest firmware 150422, and the test is normal after the machine is started.

Principle analysis:
IFM LVPS has a 3.3V activation signal. Due to J505 open circuit, IFM LVPS does not receive the activation signal and does not output, thus causing the communication between IOT and Finisher D4 to fail. After the new installation is started for the first time, IOT will automatically upgrade the matching firmware to IFM and Finisher D4 and other equipment. In this case, the automatic firmware upgrade fails due to the communication failure between IOT and Finisher D4 during the first startup, therefore, after repairing the IFM LVPS 3.3V activation signal, it is necessary to manually perform the firmware upgrade before it can be used normally.Link: https://pan.baidu.com/s/1Um25wONEPu6JpjSQ57RjZg
Extraction Code: vuyy

Tags: #Finisher D4 #047-311 #IFM #V80