Kemei color copier c754e,c654e firmware upgrade

Visitor 461 0
Problems solved
If a job is deleted due to an automatic system reset when the password copy fails and an error is displayed, the symbol is in the wrong position.MFPs with "Overwrite Temporary Data" enabled may experience a fault code C- E301 (detail code 0xC2E9) at startup.[ERBEU_1900919191]See PSCSES_1900478EN for details."Documents saved to Box from external storage cannot be viewed from PSBO.[QUBJNG1800913639]* See PSCSES_1900467 * for details.When from HDD]Account lockout may occur when the workaround for the following issue is applied: Scan to SMB via local account fails when using Active Directory (AD) authentication.[QUBJ__1800903203]
When performing scan-to-SMB by SMB 2.0 in the case of using Active Directory (AD) as external server authentication, scan-to-SMB is first performed using the name of the local PC (destination information registered on the MFP). If this fails, perform a scan to SMB using the user domain logged in to the MFP.However, if the user ID registered as destination information is specified as UPN, perform scan to SMB using only the domain user. (Do not perform scan to SMB using the name of the local PC).]How to install4.1. If the installer.    Use U disk to install. Refer to the service manual for details.U disk can be used to update the firmware conditions are as follows:-The security measures such as data encryption and password lock should be released, or the security function should be disabled.-Recommended memory is 1]-Compatible with USB version 1.0/2.0 interface-FAT32 type format-Unable to use USB flash devices that appear as multiple drives on the computer.4.2.][DEFINITIONS OF TERMS]Feature version 3: Feature version ver.Gxx-A9 and earlier.Functional version 3 MR (maintenance) version: Firmware for functional version 5 version ver.Gxx-E4.(No feature version 5 enhancements.)"Feature version 3" has equivalent functionality.Feature version 5: Firmware for feature version 5 version ver.Gxx-E4.Feature Version 3](No feature version 6 enhancements.)"Feature version 3" has equivalent functionality.Feature Version 5](No feature version 6 enhancements.)"Feature version 5" has equivalent functionality.Feature version 6: Firmware for feature version 6 version Gxx-G9/H1/H2.Feature Version 3 MR3 (Maintenance Version 3) version: Firmware for Feature Version 7 version ver.Gxx-J6/K1/K2/K5/K6/K7/K8/K9/M0.(No feature version 7 enhancements.)"Feature version 3" has equivalent functionality.Feature Version 5 MR2 (Maintenance Release 2) version: Firmware for Feature Version 7 version ver.Gxx-J6/K1/K2/K5/K6/K7/K8/K9/M0.(No feature version 7 enhancements.)"Feature version 5" has equivalent functionality.Functional version 6 MR (maintenance) version: firmware for functional version 7 version ver.Gxx-J6/K1/K2/K5/K6/K7/K8/K9/M0.(No feature version 7 enhancements.)"Feature version 6" has equivalent functionality.Feature Version 7: Firmware for Feature Version 7 version ver.Gxx-J6/K1/K2/K5/K6/K7/K8/K9/M0.]About Soft Switch Settings]Hexadecimal allocation: 60 -> functional version 7Hexadecimal allocation: 50]    Hexadecimal allocation: 40 -> functional version 5Hexadecimal allocation: 20] [Note]If you install firmware older than Gxx-E4 on the MFP, you cannot install Gxx-E4 or later through IISW.When Gxx-E4 or higher version of firmware is installed through the USB stick, Gxx-E4 or higher version can be installed through IISW. When downgrading the firmware from Gxx-H2 or later to Gxx-G9/H1, make sure that the AirPrint function (soft switch) is set to OFF. 4.2.1.]4.2.1-1. Firmware upgrade procedure from functional version 3 to functional version 3 MR3 (maintenance version 3) version.
If a loadable driver for feature version 3 is installed, remove it in service mode.Install the firmware for feature version 7 on the MFP.Turn off the main switch and then turn it on again.Install the loadable driver for feature version 7 on the MFP. 4.2.1-2. Firmware upgrade steps from feature version 3 to feature version 7.
If the audio data/loadable driver for feature version 3 is installed, remove it in service mode.Install the firmware for feature version 7 on the MFP.Turn off the main switch and then turn it on again.Change the soft switch settings in Service mode as follows.Switch No.: 25Hexadecimal allocation:]Turn off the main switch and then turn it on again.Install loadable drivers and audio data for feature version 7 on the MFP.If the MFP upgrades to firmware for feature version 7, upgrade the printer driver for feature version 6.
Because device information cannot be obtained and other problems may occur. Please also upgrade the application.
4.2.1-3. Upgrade the firmware from functional version 3 MR (maintenance version) to functional version 3 MR3 (maintenance version 3).
If a loadable driver for feature version 5 is installed, remove it in service mode.
Install the firmware for feature version 7 on the MFP.Turn off the main switch and then turn it on again.Install the loadable driver for feature version 7 on the MFP.4.2.1-4.]
If the audio data for feature version 3/loadable driver for feature version 5 is installed, remove it in service mode.Install the firmware for feature version 7 on the MFP.Turn off the main switch and then turn it on again.Change the soft switch settings in Service mode as follows.Switch No.: 25Hexadecimal allocation: 60Turn off the main switch and then turn it on again.Install loadable drivers and audio data for feature version 7 on the MFP.If the MFP upgrades to firmware for feature version 7, upgrade the printer driver for feature version 6.
Because device information cannot be obtained and other problems may occur. Please also upgrade the application.
]
If a loadable driver for feature version 5 is installed, remove it in service mode.Install the firmware for feature version 7 on the MFP.Turn off the main switch and then turn it on again.Install the loadable driver for feature version 7 on the MFP.4.2.1-6.]
If the audio data/loadable driver for feature version 5 is installed, remove it in service mode.Install the firmware for feature version 7 on the MFP.Turn off the main switch and then turn it on again.Change the soft switch settings in Service mode as follows.Switch No.: 25Hexadecimal allocation: 60Turn off the main switch and then turn it on again.Install loadable drivers and audio data for feature version 7 on the MFP.If the MFP upgrades to firmware for feature version 7, upgrade the printer driver for feature version 6.
Because device information cannot be obtained and other problems may occur. Please also upgrade the application.
]

If a loadable driver for feature version 5 is installed, remove it in service mode.Install the firmware for feature version 7 on the MFP.Turn off the main switch and then turn it on again.Install the loadable driver for feature version 7 on the MFP.4.2.1-8. Firmware upgrade procedure from functional version 3 MR2 (maintenance version 2) to functional version 7.
If the audio data for feature version 3/loadable driver for feature version 5 is installed, remove it in service mode.Install the firmware for feature version 7 on the MFP.Turn off the main switch and then turn it on again.Change the soft switch settings in Service mode as follows.Switch No.: 25Hexadecimal allocation:]Turn off the main switch and then turn it on again.Install loadable drivers and audio data for feature version 7 on the MFP.If the MFP upgrades to firmware for feature version 7, upgrade the printer driver for feature version 6.
Because device information cannot be obtained and other problems may occur. Please also upgrade the application.
4.2.1-9. Firmware upgrade procedure from MR3 (Maintenance Release 3) version of Feature Release 3 to Feature Release 7.
If you have installed audio data for feature version 3, delete it in service mode.Change the soft switch settings in Service mode as follows.Switch No.: 25Hexadecimal allocation:]Turn off the main switch and then turn it on again.Install audio data for feature version 7 on the MFP.If the MFP upgrades to firmware for feature version 7, upgrade the printer driver for feature version 6.
Because device information cannot be obtained and other problems may occur. Please also upgrade the application.
4.2.1-10. Upgrade the firmware from functional version 5 MR (maintenance version) to functional version 5 MR2 (maintenance version 2).
If a loadable driver for feature version 5 is installed, remove it in service mode.Install the firmware for feature version 7 on the MFP.Turn off the main switch and then turn it on again.Install the loadable driver for feature version 7 on the MFP.4.2.1-11. Firmware Upgrade Procedure from Functional Version 5 MR (Maintenance Edition) to Functional Version 7.
If the audio data/loadable driver for feature version 5 is installed, remove it in service mode.Install the firmware for feature version 7 on the MFP.Turn off the main switch and then turn it on again.Change the soft switch settings in Service mode as follows.Switch No.: 25Hexadecimal allocation:]Turn off the main switch and then turn it on again.Install loadable drivers and audio data for feature version 7 on the MFP.If the MFP upgrades to firmware for feature version 7, upgrade the printer driver for feature version 6.
Because device information cannot be obtained and other problems may occur. Please also upgrade the application.
4.2.1-12. Firmware upgrade procedure from functional version 5 MR2 (maintenance version 2) to functional version 7.
If you have installed audio data for feature version 5, delete it in service mode.Change the soft switch settings in Service mode as follows.Switch No.: 25Hexadecimal allocation:]Turn off the main switch and then turn it on again.Install audio data for feature version 7 on the MFP.If the MFP upgrades to firmware for feature version 7, upgrade the printer driver for feature version 6.
Because device information cannot be obtained and other problems may occur. Please also upgrade the application.
4.2.1-13. Firmware Upgrade Procedure from Functional Version 6 to Functional Version 6 MR (Maintenance Edition).
If a loadable driver for feature version 5 is installed, remove it in service mode.Install the firmware for feature version 7 on the MFP.Turn off the main switch and then turn it on again.Install the loadable driver for feature version 7 on the MFP.4.2.1-14. Firmware upgrade steps from feature version 6 to feature version 7.
If you have installed the loadable driver for feature version 5 and the audio data for feature version 6, remove it in service mode.Install the firmware for feature version 7 on the MFP.Turn off the main switch and then turn it on again.Change the soft switch settings in Service mode as follows.Switch No.: 25Hexadecimal allocation:]Turn off the main switch and then turn it on again.Install loadable drivers and audio data for feature version 7 on the MFP.4.2.1-15. Firmware Upgrade Procedure from Functional Version 6 MR (Maintenance Edition) to Functional Version 7.
If you have installed audio data for feature version 6, delete it in service mode.Change the soft switch settings in Service mode as follows.Switch No.: 25Hexadecimal allocation:]Turn off the main switch and then turn it on again.Install audio data for feature version 7 on the MFP.4.2.2. Downgrade4.2.2-1.]If you have installed audio data and loadable drivers for feature version 7, remove them in service mode.Change the soft switch settings in Service mode as follows.Switch No.: 25Hexadecimal allocation:]Turn off the main switch and then turn it on again.Install the firmware for feature version 3 on the MFP.Turn off the main switch and then turn it on again.Link: https://pan.baidu.com/s/1UaXY5b_wujn9yvQSJ3tWeQ
Extraction Code: ubah


[bizhub C754e Series] [Firmware Version GDQ-M0] Feature Version 7 Regular ROM (For Web Browser (LK-101v3)) Latest FirmwareLink:https://pan.baidu.com/s/1RwcpxlLaxTxsQAfhVukrQQ
Extraction code: a1je

Tags: #c754e #c654e #Firmware #Ke Mei

Leave a comment