Ricoh IM C2000,C2500,C3000,C3500,C4500,C5500,C6000 Chinese repair manual

Visitor 370 0
Ricoh IM C2000,C2500,C3000,C3500,C4500,C5500,C6000 Chinese repair manual


When generating a regular SC (type D), perform an automatic restart. You can use SP5-875-001 (SC automatic restart setting output) (default value: 0 "automatic restart") to set automatic restart or user operation restart.
When type D appears, automatic restart is completed or the machine displays a query to the user whether to restart. However, when SC occurs twice in a short period of time, the machine will send a report to the @ Remote server without restarting. This is because if SC occurs twice, simply restarting may not be a good solution.
After performing an automatic restart, a confirmation screen will be displayed. The confirmation screen can be cancelled by pressing the [OK] key (only when the main power switch is switched from off to on). Screen during restart
Operation during SC restart
Timing of SC restart
When @ Remote is enabled and no NRS warning * 1 is generated, the corresponding SC is automatically restarted.
*NRS warning: Issued when a regular SC (type D) is generated twice and the total counter counts 10 times.
Time for automatic restart
After the post-processing during printing and other processes is completed, restart the engine after a feasible 30 second interval.
At this point, a restart is performed even when the MFP is running. When restarting is feasible, the engine does not start process control.