Ricoh MPC4504SP boot display SC442-00 code

Visitor 347 0
SymptomsMachine boot display SC442-00 fault generationcodecontainsrighteousnessITB promotion errorEven if the ITB lifting motor (and the powder supply motor (M)) rotates, the ITB lifting sensorFailure to detect the specified sensor rod status within the specified time.
  • Attach/detach operation: If not detected within 2000 ms
  • Home operation: If not detected within 5000 ms
  • Signal detection sampling period: 10 milliseconds
  • Image transfer unit not set/wrong set
  • Sensor dirty
  • Poor sensor
  • Poor motor
  • Large unit load

1. Reset the image transfer unit correctly.2. Clean the ITB lift sensor3. Check the wire (the connector is disconnected and loose)4. Replace the ITB lift sensor5. Replace the image transfer unit6. Replacing contact/separation drive unit
WeirepairpassCheng1. Reinstall ITB unit, the fault is not solved2. Check that the wire is not disconnected or loose3. Output check transfer motor, contact/separation drive unit operates normally4. Replace ITB unit, the fault is not solved5. Clean the ITB lifting sensor, the fault is not solvedSolutionReplace the ITB lift sensor. Trouble solved.: Number AW020224 (for reference only)


Tags: #442 #ITB #Transfer printing #4504