Ricoh C360DNw display "correctly set drum unit" fault

Come back soon. 332 0

SP C360DNw/C360SFNw/ C360SNw /C361SFNw

Symptoms:

When a SPC360DNW machine is powered on, the machine displays the correct setting of the toner cartridge unit in black. The fault persists even after replacing the drum unit with a new one.

Reason:

1. Poor development unit of the photoelectric conductor.

2. Defective ID chip in black toner box

3. The new PCDU sensor board is faulty.

4. Poor connection between the sensor board and the HVPS high-voltage board.

Maintenance process:

1: When a new PCDU is inserted, the terminal installed above the cover can be detected, such as when the new PCDU contacts the three pin terminal, the fuse is opened, and the on-site inspection shows that the fuse status of the new PCDU is normal. (See the comparison photo below)

2: On site disassembly of the new PCDU sensor board was checked and found to be normal through exchange (see the attached part photo)

3: Check the connection between the PCDU sensor board and the HVPS (high voltage power supply) high voltage board, and find that the connecting harness is loose. After re plugging and unplugging the connecting harness, the machine displays that the black drum unit detection is normal, and the fault is resolved. (See the photo below)

Solution:

Reinstall the HVPS (high voltage power supply) and resolve the connection fault with the high voltage detection contact point.

Tags: #C360SFNw #C360DNW #C361SFNw #Correctly set the toner cartridge