| Symptom: During the production process of Pro C5200S at the customer's site, an error code SC486-00 was reported. The waste powder bottle was emptied normally, but after shutting down and restarting, the error code reappeared after a while of production. Reason: According to the maintenance manual SC486-00, it was found that there was an error in the detection of the waste toner bottle sensor. At the same time, the following description was found in the "Detailed Description" section of the manual: 1. The gear is not rotating under load. 2. The sensor is damaged or dirty, and continues to emit signals. Solution: 1. Upon arrival at the scene, check the SC error record. Check the status of the waste powder bottle. 2. Plan to remove the waste toner bottle unit from the back for inspection according to the maintenance manual. But through observation, it was found that the motor operation and sensor cleanliness can be observed through gaps. 3. When the equipment was powered on and the output was checked, SP5805-114 found that the motor and gears were operating normally. It should be due to the sensor. After shutting down and cleaning the sensor, the device was tested again and returned to normal. Finally, other locations related to the waste powder bottle were checked. 4、 It is important to review and summarize the on-site environment. If customers encounter similar situations when using humidifiers on site, it is recommended to use large air conditioning fans, which can also have a humidifying effect but will not cause water or alkali. When encountering faults, observe more and avoid excessive maintenance. After dismantling a lot, it was found that it could actually be solved without dismantling. Can effectively improve maintenance speed. If we had directly chosen to dismantle the IH flip frame and AC drive board, and then dismantled the waste toner bottle unit for inspection. |
Tags: #SC486 #c5300 #C5200 #c5100 #Waste powder sensor