Symptoms: The customer reported that during the printing process, the upper part of the machine suddenly appeared blurry, but there were no other abnormal noises or phenomena.
Reason:The fixed bearing on one side of the transfer roller on the secondary component has fallen off, resulting in inconsistent height before and after transfer. There is a gap between the transfer roller and the transfer bias roller during printing, leading to poor transfer.
Solution:
Firstly, during the printing test, it was discovered that the side of the paper near the back of the machine was printing with a loose or uneven texture. Due to the previous occurrence of uneven pressure between the fixing roller and the hot belt, one side became weak. First, rule out whether it is a fixing problem.
Open the front door of the machine, shield the sensor, print for testing, and wait for the paper to pass through the second rotation before reaching the fixing device. Upon opening the front door, it was found that the image on the paper had already been transferred to the track and had become blurred. Therefore, the problem with the fixing device was ruled out.
Further investigation revealed that there was a gap between the second wheel powder replenishment and the transfer bias roller on the side that entered the rear of the machine when lifted. After pulling out the large drawer and removing the second wheel, it was found that the transfer roller on the second wheel could sway left and right. Further inspection revealed that the fixed bearing on one side of the transfer roller had fallen off and displaced. Due to the lack of spare transfer rollers on site, the replacement of the secondary component resulted in normal printing during testing
Tags: #Secondary transfer #8300 #8310 #Partial hair deficiency #Transfer bias roller