Symptom: The exhibition hall reported that the Fiery server cannot be connected to 83, but Fiery can be started. Through remote desktop viewing, the taskbar at the top shows that it is starting. According to the exhibition hall DPC, multiple attempts to restart Fiery server have been unsuccessful, SP code confirmation, and resetting the Android screen have also been ineffective. Reason: 1. First, we verified once and the customer's statement is still invalid 2. SP code, invalid after 5-801-2. 3. Considering that Fiery is connected to the host through SP code recognition and needs to connect to an external controller, no reset processing was performed on the Android system. Upon checking the host SP code settings, it was found to be normal. Therefore, it was decided to reinstall the 83 server Solution: 1. Create a USB flash drive for reinstalling the 83 server using the builder program 2. After reinstalling Fiery, it was able to connect smoothly with the host. After inquiry, the showroom conducted a demo test, and with Fiery and GW enabled simultaneously, SLNX V3 software was pushed, which theoretically only pushes to GW. But in the case where Fiery is also connected to the host, it is possible to tamper with the program on Fiery. It is recommended to disconnect the Fiery server when installing the solution software. |
379
0
Address of this article:https://073868.com/post/3364.html
Copyright Notice:
For relevant infringements, reports, complaints and suggestions, please send E-mail:weixiuwang68@qq.com
Previous articleRicoh Pro C5300 startup report code SC540-00