Symptoms
A Ricoh IMC2500 printing and copying machine may exhibit blackening and black background phenomenon
Possible causes:
PCU malfunction/developing unit malfunction/ITB malfunction/BICU board malfunction/LDU malfunction
Maintenance process
1. On site inspection of the fault situation shows that the machine can print and copy normally in black and white mode. However, once the machine switches to full-color mode, the fault phenomenon shown in the picture will occur;
2. Considering that the ITB component of the machine will make contact with the colored PCDU part through the cam in full-color mode, replacing the ITB component for testing still resulted in the fault;
3. Replace the colored PCDU component for testing, and the fault persists;
4. Print SP-2109 full point image to check for specific color faults, and find that all colors have poor image performance
5. Replace the black PCDU unit for testing, but the fault persists;
6. Recheck whether the HVP (CB) charging contacts of the machine are normal. It was found that the contact angle was too large. After correction, the image was tested again and found to be normal. The specific location is marked as C in the following figure:
Special reminder:
This type of image malfunction may also be related to charging, in addition to abnormal PCDU and ITB;
Solution
The fault was repaired after recalibrating the HVP (CB) contacts;
Tags: #ITB #Transfer printing #c2500 #HVP #Black PCDU