Ricoh IM C3000 drive gear makes noise, horizontal white line

Visitor 418 0
Symptoms
When printing/copying a large number of tasks continuously (such as AB model: 2.4k/day, YZ model: 2.2k/day), the following symptoms may occur
  • The driving gear of the color developing unit emits noise
  • Horizontal white line


Affected models:
AB model:
IM C3000/IM C3500/MP C3004ex/MP C3504ex/MP C3004/MP C3504 (C, M, Y)
Yz model:
IM C2000/IM C2500/MP C2004ex/MP C2504ex/MP C2004/MP C2504 (Bk, C, M, Y)
notes:
The maximum ACV (monthly) for AB model is 20k, while for YZ model it is 10k
When the machine is continuously printing/copying, the cooling fan will lower the temperature around the developing unit. However, due to long-term continuous operation and differences in installation environment, the cooling inside the developing unit cannot be completed normally. Therefore, the temperature of the toner inside the developing unit will increase, leading to abnormal noise or white lines. If continuous operation continues in this situation, the driving unit of the developing unit may be damaged.

Reason
In the above situation, the temperature of the drive shaft in the developing unit exceeds the temperature specified in the specifications.
Solution
Set the following SP modes to the "set values" shown in the table

notes:
  • Under the above conditions, the temperature inside the developing unit can be reduced by performing cooling more frequently.
  • However, this will also reduce productivity (ab model: 30ppm → 12ppm, yz model: 20ppm → 6ppm), as the machine must stop working in order to cool down.
  • The reason for changing the value of SP1-995-004 is that it is the optimal value for extending the duty cycle
  • The temperature inside the developing unit cannot be lowered by simply turning on the fan. In order to effectively complete equipment cooling, it is necessary to extend the duty cycle time. When the default value of this SP is 33, the cooling fan will turn on too early and cannot start the duty cycle. As a result, the temperature inside the developing unit increased and the unit could not cool down properly (it could cool down when set to 41)
Ab Model: IM C3000/IM C3500/MP C3004ex/MP C3504ex/MP C3004/MP C3504
SP Description default value Set as:
1-955-004 Dev Cooling Fan Op Sw Temp *33 41
2-990-008 Down-time_BW: Duty Control 25000 60000
2-990-009 Down-time_FC: Duty Control 25000 60000
2-990-010 Ambient Temp Correction Coeff 0 -0.4

yz Model: IM C2000/IM C2500/MP C2004ex/MP C2504ex/MP C2004/MPC2504
SP Description default value Set as:
1-955-004 Dev Cooling Fan Op Sw Temp *33 41
2-990-008 Down-time_BW: Duty Control 60000 60000
2-990-009 Down-time_FC: Duty Control 60000 60000
2-990-010 Ambient Temp Correction Coeff 0 -0.4

Tags: #White line #Abnormal noise #C3504ex #C3000 #C2004