Ricoh MP2500 SC411 fault

Visitor 317 0
MP2500 has encountered SC411 malfunction, and multiple solutions have been attempted but have not been able to resolve it. The specific solution is as follows:
1. Cleaning the transfer printing unit discharge plate is ineffective;
2. Replacing the high-voltage board is ineffective;
3. Replacing the transfer roller is ineffective;
4. Replacing the BICU board is ineffective;
5. Replace the copy paper with a new packaging, temporarily alleviate the issue, but the problem persists;

Reason
Due to the accumulation of some carriers and toner in the gaps of some plastic parts in the transfer unit after the machine has been used for a long time, these carriers and toner can easily cause leakage of the high-voltage contact plate of the transfer unit, resulting in SC411 malfunction.

Solution
Dismantle the entire transfer bracket (as shown below), and carefully clean the accumulated carrier and toner in the transfer unit by disassembling it. Then reinstall it and solve the problem;

Tags: #411 #2500