Symptom: MC2000 reports SC672-01 code Analysis process: 1. After re plugging and unplugging the controller board and BICU board, the power on test showed that the fault still persisted. 2. Replace the controller board for testing, and the startup fault persists. 3. Replace the BICU board for testing, and the fault persists. 4. Replace the SRAM on the BICU for testing and troubleshooting. Solution: After replacing the SRAM on the BICU board, the fault was resolved. |
360
0
Address of this article:https://073868.com/post/3206.html
Copyright Notice:
For relevant infringements, reports, complaints and suggestions, please send E-mail:weixiuwang68@qq.com
Previous articleRicoh IMC2500 printing and copying are light in the middle.
NextRicoh C2503 enters sleep state and cannot be restored or printed.