Ricoh HQ9000 Kissinger CP6346 machine boot display code SC-211

Visitor 334 0
Symptoms
After the machine is turned on, the fault code SC-211 is displayed

Reason
The MPU board or IO board of the machine is defective;
Poor pressure release motor of thermal head;
Poor pressure release sensor;
The contact wire harness of the plate making unit is poor.


Maintenance process
On-site maintenance measures:
1) Replace the MPU board IO board, the fault still exists;
Replace the pressure release motor, but the fault still exists;
3) Replace the pressure release sensor, the fault still exists;
4) Clean the wiring harness of the plate making unit (as shown in part 7 in the figure below), the test run is normal, and the fault is resolved.

Tags: #SC211 #HQ9000 #CP6346 #Plate making unit