Symptoms The M C2000 does not respond when turned on, the screen does not light up, and the machine has no action Reason 1. Power board malfunction 2. SOP screen malfunction 3. BICU board malfunction 4. Controller board failure Measures 1. Replace the power board, but the fault persists; 2. Replace the SOP screen, but the fault persists; 3. Replace the BICU board, but the fault persists; 4. Replace the controller board normally Solution Replace the controller board and solve the problem. |