Ricoh HQ9000 Printed Image Missing, Image Missing Position

Visitor 334 0
Symptoms
The print image is missing, and the location of the missing image is uncertain.
Reason
Defective machine plate making department or thermal head.
The SBU board of the machine scanning department is defective.
The machine MPU board is faulty.
The connection between the machine plate making department and the MPU is poor.

Maintenance process
On-site maintenance measures:
1) Using SP8-5-1 to print TH test graphics, the fault persists, and the relationship between the malfunction caused by a faulty SBU board in the machine scanning department has been ruled out.
2) No abnormalities were found during the inspection of the plate making department. The thermal head was replaced, but the fault persisted.
3) Replace the MPU board, but the fault persists.
4) When checking the wiring harness between the machine plate making department and the MPU, it was found that one of the pins in the plug was skewed, and the data cable could not be connected properly. The pin position was readjusted and the fault was resolved.
There is a problem with the wiring harness. The plug position is shown in the following figure:

Tags: #HQ9000 #thermal head #Image missing

Leave a comment