Ricoh IMC3000 toner cartridge is abnormally worn with scratches

Visitor 328 0
Symptoms:
About 30000 pieces of IMC3000 were used, and a magenta background gray appeared on the back of the machine. After disassembly, it was found that the drum surface was abnormally worn, while other drums showed no signs of wear. After replacing with a new PCDU and using about 5000 pieces of magenta drums, the same problem occurred again, but the new drum did not show any background gray problem.


Analysis reasons:
After the surface of the drum wears and ages, it will cause insufficient voltage on the drum after charging, resulting in bottom dust and increased load on the scraper and waste powder recovery, causing damage. The drum surface will not be scraped clean, resulting in quality problems with the strip mounted image. If the drum surface is not scraped clean, it will also dirty the charging roller, causing uneven charging and leading to a vicious cycle. After replacing with a new PCDU and using thousands of pieces, the drum gauge has worn out again, and it is a serious uneven wear on the rear end of the machine. The first consideration is contact wear.

Measures:
1. Based on the uneven wear and the appearance of a magenta drum, this fault occurs. The usage of PCDU is not significant, and the influence of the drum, carrier, powder, and scraper can be ruled out. But still check the waste powder recycling pipeline, there is no blockage and there is not much residue left.
2. Check that the ITB magenta transfer roller bracket operates normally.
3. Check the charging and developing bias of the drum. After replacing the HVP-CB test, the abnormal wear did not worsen. After replacing it with a new PCDU and testing 5000 sheets, there was no further drum surface wear.

Solution:
After replacing the drum charging and developing high-voltage board (HVP-CB), the fault was resolved.