Symptom: After the drum stops during the power on self-test, an E-01 code is reported. Diagnostic process: 1. Test the main motor through the help mode HELP-05, and if the drum does not rotate, report the E-01 code directly. 2. Replace the main motor substrate removed from the normal machine for testing, and the fault persists. 3. The fault still persists after replacing the main motor. 4. Reset the main motor and main motor substrate removed from the normal machine to the normal machine, and also report the E-01 code after startup. 5. During the inspection of the main motor substrate, it was found that the varistor was burnt out due to a short circuit in the main motor. Both boards were burned. (Below image)
6. After replacing both the main motor and the main motor control board, the machine returned to normal and the fault was eliminated. Solution: After replacing the main motor and main motor control board, the problem was resolved and the issue was resolved. Note: The fault is caused by a short circuit in the main motor, resulting in the burning of the main motor control board. The probability of this situation occurring is relatively low. Suggest replacing both the main motor and the main motor control board for testing! (Before replacing the board, be sure to carefully confirm that the electrical components on the board are not burnt out to prevent the newly installed board from burning out) |