Symptoms Fault: An error message appears when a DD5450C machine is turned on: EOO1 is displayed. Reason E001 Description: Main motor encoder sensor output error. 1. The drive system gears are damaged or obstructed by foreign objects, 2. The encoder sensor of the main motor is faulty. 3. The main motor behind the drum is faulty. 4. Main motor substrate malfunction. Maintenance process The on-site engineer used a jog switch to test that the main motor cannot rotate, and checked the output status of the encoder sensor of the main motor with HELP-005. Remove the rear cover plate and check if the gears of the drive system inside the machine are damaged or obstructed by foreign objects, resulting in excessive load. Confirm that the drive components are normal. Replace the main motor (part number C2841132DP: MAIN: MOTOR1) with a new one, and the machine still has a malfunction. Measure the voltage between CN51-5 (+24) and CN51-1 (GND) of the 24V power board with a multimeter, and confirm that the power board output is+24V, indicating that the power board is functioning properly. 5. Remove the main motor substrate and observe that there are burnt marks on two electronic components on the main motor drive board. It is basically judged that the main motor substrate is damaged (see red circle in Figure 2 below). After replacing the main motor substrate, the machine fault was eliminated.
|
Tags: #EOO1 #5450C #Main motor