Symptoms: The newly installed machine will receive a prompt message such as' Internal error occurred 'upon startup, followed by the code' SC672-20 '. Analysis of causes and measures: According to the code explanation in the maintenance manual, first check the USB cable and related wiring harness; 1. Check the wiring harness connections of the board (controller, IPU, BCU, SOP) and no issues were found; 2. The firmware version is low, upgrading the firmware package and upgrading the system firmware from V 2.27 to the latest V 3.53 cannot solve the problem. 3. Check and reconnect the hard drive, but it still cannot be resolved; 4. Check and reinstall the NVRAM chip, the fault was briefly resolved, and the SC672-20 code appeared again the next day; 5. Replace the controller board and test continuously for several days, and the machine can work normally. Solution: Replace the controller board and troubleshoot. |