Symptoms: MP2001SP copies and prints all black. Analysis of possible causes of failure: 1. Poor charging roller. 2. Poor OPC drum. 3. Poor high-voltage board. Measures: 1. Check that the charging roller and drum are in good condition and installed correctly 2. Replace with normal PCDU and high-voltage board for testing, and the fault phenomenon cannot disappear. 3. Replace the BICU and controller board for testing, but the fault cannot be eliminated. 4. Replace the laser unit for testing, and the fault disappears. But after printing a few copies, the malfunction reappeared. 5. Simultaneously replace the BICU board and laser unit for continuous testing, and eliminate the fault. Cause of the failure: It is determined that the poor quality of the BICU board has affected the control of the laser unit. |