Ricoh C5503 Change Transfer Belt After Jump SC442 and SC370-02

Visitor 349 0
  • SC442, observe the ITB contact motor for rotation after opening the front door and holding the door switch, test code SP5-804-150. This can be observed by watching the rotation of the cam in the blue box (Figure 1). Also use the test code SP5-803-029 to observe the ITB contact sensor for a 0/1 change.
  • During the test, it was found that the ITB contact motor had rotating action, eliminating the problem of the transmission mechanism. However, the ITB contact sensor has no 0/1 change, and it is preliminarily judged that the sensor is dirty or defective.
  • Test after cleaning the sensor, when the sensor is blocked with paper, the sensor value 0/1 changes, and the sensor is not good.
  • Continue to test after the machine, the phenomenon remains the same.
  • After plugging and unplugging the ITB unit for many times, the SC442 can not be skipped occasionally, but the SC370-02 can continue to be skipped.
  • After cleaning the ID sensor test, the phenomenon is still.
  • A look at the ID sensor board shows that this model has a valve that shades the sensor. (Figure 2. Figure III)
  • Suspected valve position deformation, test normal after removal

Tags: #SC442 #SC370-02 #Sensor C5503