Ricoh MP5055SP operate slowly in Greenland environments

Visitor 339 0
An MP5055SP runs slowly in the Greenland software environment, and the response time for adjusting the interface and sliding screen is too long; Entering the system does not respond (all icons are gray)

Possible causes:
Greenland software/controller board/hard drive
Maintenance process
1. Confirm that the machine enters CAP, ELP, or administrator tools very slowly after user or administrator login, with a delay of more than three seconds, which causes great inconvenience to customer operations;
2. After confirming with the maintenance engineer, the machine itself did not show any code (SP7-403) after the problem occurred;
3. Restarting the machine or restarting the CAP/ELP service is ineffective;
4. Check that the machine heap and stack sizes are 16MB/256KB respectively. After adjusting the heap and stack to 64MB/512KB, the fault still persists;
5. Reinstall and install the Greenland software, but the issue persists;
6. Upon inspection, it was found that the software's log server has been specially configured to not only require the existence of an MFP local hard drive, but also to upload to the customer's designated PC server. Disabling this feature further exacerbates machine latency;
7. After deleting the content of the log server, the machine operates normally, but the fault will still occur after a period of use;
8. Replace the machine's hard drive for testing, restore the machine's operating speed to normal, and repair the fault;

Solution
Troubleshooting by replacing the HDD unit;

Tags: #hard disk #Greenland #Controller board #Slowly #5055

Leave a comment