iR-ADV DX C3720/3725/3730 [Failure Phenomenon] The error code of the new machine installation boot prompt is E280-0003. [Cause of Failure] Bad main controller board. [Maintenance measures] After replacing the main controller circuit board (FM1-W597-000), the fault is resolved. |