HP CP1025 series engine maintenance experience

Visitor 384 0
I believe many engineers are not very skilled at repairing this printer Today, I will explain to you how to analyze and determine the malfunction of this machine This machine can also be borrowed from printers such as M177176 All belong to the same platform
First, let's take a look at the self check
Under normal circumstances, the self checking mechanical action process of this platform printer after power on is as follows: heating component - drum - heating component and belt rotate together, and finally ready.
So from the self check, it can also be seen that the machine only reported an error at that step Can roughly determine the direction of the problem


Determine the problematic component based on the length of time
As mentioned earlier, if the self check time is short and the two lights stay on after less than 5 seconds of startup, it is usually due to a problem with the heating component If it's about 15 seconds, it's the drum. If two lights come on after 30 seconds, it's usually because there's a problem with the belt


Imaging
Due to the fact that this consumable is used for four imaging processes, it needs to be rotated four times by the machine for each color file printed. If the rotation is frequent and there is a slight deviation, the machine will report that the power light and exclamation mark lights are constantly on. How to determine if the consumable is in place? When the machine stops running, you can open the cover to check if the consumables have been turned to the correct position, which can determine whether the problem is caused by consumables.


After a long self check process, the machine experienced two constant lights on
Perhaps the belt did not pass the self check and there are two white spots on the belt. You can gently wipe one white spot on each side It can be solved