Ke Mei C4070 Solution for Printing White Stripes (Bands) of Photosensitive Drum Components with White Lines in Full Edition
Visitor3730
AccurioPress C12000,AccurioPress C14000,AccurioPress C4070,AccurioPress C4080,AccurioPress C6085,AccurioPress C6100,AccurioPrint C4065,bizhub PRESS C1100
(1) ProblemThe problem that cannot be improved even by cleaning the dustproof glass of the charging component and writing part in monochrome.The issue is vaginal discharge/stripes, which looks like the photo below.It mainly occurs in the middle and end of the service life of the photosensitive drum components.But in rare cases, slight white discharge may also appear on the new photosensitive drum assembly.
(1) ReasonThis problem occurs when the lubricant is unevenly applied to the photosensitive drum.-When brand new: Due to poor fit between the lubricant and the brush (or slight initial inclination of the brush), uneven axial application of lubricant occurs, resulting in this problem.-Mid service life: External additives in the developer accumulate between the lubricant rod and brush, causing uneven axial application of lubricant, resulting in this problem.
(2) SolutionExecute the 'Drum refresh mode' as needed.However, the corresponding relationship varies depending on the model, so please refer to the table below before execution.
If the problem occurs in the early stage of the service life (new photosensitive drum components) and the degree is relatively mild, it can be restored with sufficient cooperation, so performing * times this operation can achieve sufficient effect. However, if it occurs in the middle of the service life, the condition of the lubricant surface needs to be changed, so the number of times it needs to be performed depends on the severity of the problem. In addition, it may not be possible to fully recover.Please confirm the maximum number of times, execute less than the maximum number, and check the effect.
AttentionWhen replacing a new photosensitive drum component, it is necessary to perform "Gamma Auto Adjustment", "Color register Auto Adjustment", and "Maximum density Initial Adjustment". After performing the above three adjustments, if white lines can be seen on the image, then execute the "Drum refresh mode".
Model
The number of times the "Drum refresh mode" is executed
Brand new (* 1)
Mid life (* 2)
C4080 series
Execute 'Drum refresh mode' (photosensitive drum cleaning mode)2(Two) times, check its degree. Up to 10 times
Execute 'Drum refresh mode' (photosensitive drum cleaning mode)2(Two) times, check its degree. Up to 10 times
C7100 series
Execute 'Drum refresh mode' (photosensitive drum cleaning mode)2(Two) times, check its degree. Up to 10 times
Execute 'Drum refresh mode' (photosensitive drum cleaning mode)2(Two) times, check its degree. Up to 10 times
C14000 series
Prohibited (* 3)
Cleaning mode of photosensitive drum 2:Up to 3 times
C6100 series
Prohibited (* 3)
Cleaning mode of photosensitive drum:Up to 3 times
C1100 series
Prohibited (* 3)
Cleaning mode of photosensitive drum:Up to 2 times
C3080 series
non-functional
C2070 series
non-functional
C1070 series
non-functional
*1: Please note that due to different mechanical configuration conditions around the photosensitive drum and different operations when performing the photosensitive drum cleaning mode, some models enable this function while others disable it.*2: Please note that due to the reasons mentioned in * 1, the maximum number of executions may also vary.*3: Please do not perform cleaning mode on the brand new photosensitive drum. Otherwise, the lubricant on the photosensitive drum may not be sufficient, resulting in damage to the cleaning scraper or photosensitive drum.
<参考>Steps to execute the 'Drum Refresh mode'
C4080 series/C7100 series [Expert Adjustment] → [Execute Adjust Operation] → [Drum Refresh Mode]
C14000 series/C6100 series/C1100 series[Adjustment] → [Execute Adjust Operation] → [Drum Refresh Mode]
Ke Mei C14000,C7100,C4080 Quick Reading Guide 1. About Quick Guide The quick guide provided for each product outlines the information required to use this system in an easy-to-understand manner. Before using this system, please read...
This instruction describes how to initialize the administrator password and service password MX3050/3060/3070/3550/3560/3570/4050/4060/4070N series default. Please note that once...
problem description:-the user's ns MFP1005/ns 1020 after use for a period of time, when continuous printing, there will be print content intermittent up the problem, as shown in the figure below the cause of the problem:-after use for a period of time,...
Involving models: M104/M132/M203/M227 series fault phenomenon:-the right gear set has a very large continuous sound of gear tooth hitting during power-on self-test, and then the panel prompts 59.C0 or the ready warning light is always on...
fault: hp Laserjet pro m128fp mfp printing paper jam, paper card in the heating components, print fonts and patterns have stretch stretch deformation fault analysis: 1. engineers on the machine line a simple test...
Suitable products: M1005,M1020 Fault Description: The printer does not stop feeding paper. The customer sends and repairs an M1005 printer to start up and does not stop feeding paper. Generally, this situation is mostly related to relays (clutches). as shown in figure 1: red...
Failure phenomenon: CP1025NW cannot install WIFI printer failure analysis: customers reflect that the machine has been unable to install wireless printing function. Prompt for password every time. No password was previously set. door detection first with usb cable even...
HP laser printer (especially multifunction machine) outlet has water vapor condensation instructions [*] water vapor and printer has nothing to do with, the printer itself does not produce water vapor [*] water vapor is because the printed paper moisture, in the heating process is evaporated out...