Fault Description: Send for repair a M1136 printer printing bias Resolution process: The machine comes with original consumables, and the original consumables are also replaced for testing. The printing is still weak. Having ruled out consumables, continue to rule out other issues. Check whether the toner cartridge contact point and the high-voltage contact of the transfer roller are in place. Clean the light transmission baffle and the reflector head in front of the laser. Check whether the connection line of the main board connected to the power board is loose
Print sample, very light color
Check whether the connection line of the main board to the power supply board is loose and the metal is not fully inserted in place. Share summary: Under normal circumstances, the print usually does not appear faded. The reason for the weak printing may be that the customer used powdered consumables, not the original consumables. The machine is more than one year or longer. At this time, we can consider whether the laser is too dirty or the consumables are caused, eliminate the consumables, and then clean the laser. We cannot solve the problem and then consider whether it is caused by a loose connection line of the printer, or check whether there is foreign matter involved in the heating junction. If the above operations do not solve the problem, please replace the laser. The imaging principle is familiar with the chest, carefully observe the failure phenomenon, accurately judge and quickly solve it. |
Tags: #M1136 #Print #Light color #Laser #Connecting cable