| Phenomenon: A4 paper fed along the long edge gets jammed at the CIS in the drawer unit [no successful retrieval of paper library data]; after replacing with A3 paper, the paper feed test passes. Maintenance steps: 1. Look at where the alignment cam is, use a multimeter to check whether the resistance of the sensor is OK, and replace it with a sensor or a card. 2. The alignment roller code detection sensor is wiped or not. 3. The motor does not rotate during the SP5-804-149 test transfer time limit-the right drawer unit DUB/DRB board replacement has no effect. 4: it is also invalid to rotate the white film with AB glue to repair and smooth the alignment unit. [Note that the jammed paper passes through the alignment unit, but there is no paper out. A4 long side paper feed card, A3 long paper does not get stuck. 】 5: When looking at the rear panel, it was observed that the wire harness was pressed and broken by screws, causing the wire harness to fail to transmit current signals, resulting in paper jam 031.6: reconnect and wrap the wire harness, and test the paper output to be normal. |