Product Model: imageRUNNER 2725 imageRUNNER 2730 imageRUNNER 2735 imageRUNNER 2745 imageRUNNER C3226 Topic: Precautions for replacing the main controller circuit board. [Description] When replacing the main controller circuit board, it is necessary to record the parameter values on the maintenance label [a]. [Reference] As shown in the figure below, the repair label [a] is attached to the inside of the front cover plate [1] of the host
Due to changes in product specifications, a parameter in the "Front and Rear Linear Adjustment" option no longer needs to be recorded in the items printed on the repair label. Therefore, when replacing the main controller circuit board, please follow the instructions in [Maintenance Measures]. [Maintenance measures] The following 16 items on the repair label have had their functions removed due to specification changes, and no parameter values need to be entered for them. If numerical input is made, it will not affect the functionality of the host. - DFCH-R2 - DFCH-R10 - DFCH-G2 - DFCH-G10 - DFCH-B2 - DFCH-B10 - DFCH-K2 - DFCH-K10 - DACH2R2 - DFCH2R10 - DFCH2G2 - DFCH2G10 - DFCH2B2 - DFCH2B10 - DFCH2K2 - DFCH2K10 |
332
0
Address of this article:https://073868.com/post/2687.html
Copyright Notice:
For relevant infringements, reports, complaints and suggestions, please send E-mail:weixiuwang68@qq.com
Previous articleHP 103,108,131,133,136,138 enters repair service mode
NextThe printed image may be rotated 90 degrees when printing to custom size paper from the C360i