Location: Alignment color block detection sensor component Topic: The machine prompts error code E020-0081 or warning codes 34-0002 and 34-0003 during the process of performing automatic color displacement correction. [Failure Phenomenon] All models with affected serial numbers include connected shutters with short branch pipes. The failure of automatic color shift correction will result in error code E020-0081 or warning codes 34-0002 and 34-0003. -E020-0081: Lower limit error of ITB basic light intensity -34-0002: Image Position Correction Color Block Detection Warning 2 -34-0003:10 attempts to read automatic alignment pattern combinations failed and ended in pause state [Cause of Failure] This product includes shutter components with short branch pipes [a]. When the shutter is about to detach from the branch, the situation shown in [B] will occur. Once the shutter action fails, it will result in fault code E020-0081. The figure [A] shows the situation where the connecting shutter with a short branch pipe is at an appropriate height.
[Factory measures] The connection shutter component (FC8-1775-000) was improved by removing the short branch pipe. Currently, it can be confirmed that all models with affected serial numbers will include short branch pipes when connecting shutter components. [Maintenance measures] When the machine with the affected serial number experiences the above-mentioned malfunction, please prepare a new model of alignment color block detection sensor component (FM3-4717-010) and replace it. |
332
0
Address of this article:https://073868.com/post/2653.html
Copyright Notice:
For relevant infringements, reports, complaints and suggestions, please send E-mail:weixiuwang68@qq.com