After Xerox S2110ESS or CIS and its superior components are replaced, the machine reports the processing method of 062-380 or 062-371

Visitor 299 0
After Xerox S2110ESS or CIS and its superior components are replaced, the machine reports the processing method of 062-380 or 062-371
Summary
Due to firmware version matching issues, DC S2110 may report 062-380 or 062-371 codes after replacing ESS (disassembled parts) or CIS and its higher-level components.

Content:
The handling method for machine reporting FC 062-380 or 062-371 after replacing CIS and its superior components:
a) Confirm if the firmware version of the machine is 1.0.5 or higher. If it is lower than 1.0.5, please upgrade to 1.0.5 or higher
b) View the value of NVM 715-492
i. If the current value is' 0 ', please change it to' 3 '
Ii. If the current value is "3", please change it to "0"
c) Adjust and calibrate IIT according to maintenance manual 4.3 and 6.4.2.12.
d) Confirm if all functions of the machine are functioning properly.
Replacing ESS or EEP-ROM according to the ESS PWB replacement process in the maintenance manual will not generate any codes. Only when replacing the ESS PWB+EEP-ROM with other machine information or replacing the entire set of brand new ESS PWB (including EEP-ROM), can the 062-380 or 062-371 code be reported. The processing method for reporting code is the same as above.

Note: Firmware versions lower than 1.0.5 cannot read the values of NVM 715-492.